Part 1 of DIN 5035 provides definitions and general requirements for artificial lighting. Part 2 of DIN 5035 defines guideline values for workplaces indoors and outdoors. The table below lists the guidelines for illuminances to DIN 5035 Part 2, Workplaces, Extract (September 1990). Workplace Regulations ASR 7/3 and DIN 5035 Part 2 define rated illuminances for workplace lighting. ASR 7/3 was issued by the German Federal Ministry for Work and Social Order. The prescribed rated illuminances are minimum values.
| Room / activity |
En [lux] |
LC |
CR |
QC |
Comments |
| General rooms |
| Walkways in storage rooms |
50 |
ww / nw |
3 |
3 |
|
| Storage rooms |
| Storage rooms for similar or bulky goods |
50 |
ww / nw |
3 |
3 |
High-pressure sodium lamps with colour rendering group 4 permitted |
| Storage rooms with dissimilar goods in which searches are carried out |
100 |
ww / nw |
3 |
3 |
| Storage rooms in which reading is carried out |
200 |
ww / nw |
3 |
2 |
| Automatic high-bay warehouses |
| Walkways |
20 |
ww / nw |
3 |
3 |
|
| Control desk |
200 |
ww / nw |
2A |
1 |
| Dispatch |
200 |
ww / nw |
3 |
2 |
| Rest rooms, wash rooms |
| Wash rooms, canteens |
200 |
ww / nw |
2A |
1 |
Lighting to suit the mood, possibly incandescent lamps |
| Rest rooms |
100 |
ww / nw |
2A |
1 |
| Rooms for physical exercise |
300 |
ww / nw |
2A |
1 |
| Changing rooms |
100 |
ww / nw |
2A |
2 |
Possibly with additional mirror lighting |
| Laundry rooms |
100 |
ww / nw |
2A |
2 |
| Toilets |
100 |
ww / nw |
2A |
2 |
| Wash rooms, first aid rooms, medical treatment rooms |
500 |
ww / nw |
1A |
1 |
|
| Building installations |
| Machine rooms |
100 |
ww / nw |
3 |
3 |
|
| Power supply and distribution rooms |
100 |
ww / nw |
3 |
3 |
| Telex rooms, post rooms |
500 |
ww / nw |
2A |
1 |
| Telephone exchange rooms |
300 |
ww / nw |
2A |
1 |
| Walkways in buildings |
| for people |
50 |
ww / nw |
3 |
3 |
Rated illuminance matched to adjoining rooms:
En1 >= 0,1 En2
dabei bedeuten:
En1=En of walkways
En2=En of neighbouring rooms
|
| for people and vehicles |
100 |
ww / nw |
3 |
3 |
| Stairs, escalators and travellators |
100 |
ww / nw |
3 |
3 |
| Loading ramps |
100 |
ww / nw |
3 |
3 |
| Automatic conveyors near walkways |
100 |
ww / nw |
3 |
3 |
| Halleneinfahrten (during day) |
2 x En1)
min. 400 lx |
ww / nw |
3 |
3 |
nur Leuchten ohne leuchtende Seitenteile verwenden
1) En des anschlie�enden Innenraumes. Es ist der Innenbereich der Halleneinfahrt zu beleuchten. |
| Halleneinfahrten (during night) |
0,5 En2)
bis
0,2 En1) |
ww / nw |
3 |
3 |
nur Leuchten ohne leuchtende Seitenteile verwenden
2) En des anschlie�enden Innenraumes. Es ist der Aussenbereich der Halleneinfahrt zu beleuchten. |
| Offices and the like |
| Offices with daylight-oriented workplaces exclusively directly near windows |
300 |
ww / nw |
2A |
1 |
Workplace-oriented general lighting at least 0.8 En |
| Offices |
500 |
ww / nw |
2A |
1 |
Open-plan offices
- high reflectance |
750 |
ww / nw |
2A |
1 |
High reflectance: ceiling at least 0.7. walls/partitions at least 0.5. Individual workplace lighting permitted |
Open-plan offices
- average reflectance |
1000 |
ww / nw |
2A |
1 |
| Technical drawing |
750 |
ww / nw |
2A |
1 |
En
Angle of drawing board75 degrees from the horizontal; at a height of 1.2 mat the mid-point |
| Rooms with seating and meeting rooms |
300 |
ww / nw |
2A |
1 |
|
| Reception rooms |
100 |
ww / nw |
2A |
1 |
| Rooms frequented by the public |
200 |
ww / nw |
2A |
1 |
| Rooms for data processing |
500 |
ww / nw |
2A |
1 |
For standards for computer workstations see DIN 5035 Part 7 |
| Wholesale and retail premises |
| Sales rooms |
300 |
ww / nw |
2A |
1 |
|
| POS workplaces |
500 |
ww / nw |
2A |
1 |
|
| Trade and commerce (selection) |
| Derusting and painting steel components |
200 |
ww / nw |
3 |
2 |
|
| Pre-assembly of heating and ventilation systems |
200 |
ww / nw |
3 |
2 |
| Locksmiths and plumbers |
300 |
ww / nw |
3 |
2 |
| Vehicle workshops |
300 |
ww / nw |
3 |
2 |
| Machine repair workshops |
500 |
ww / nw |
3 |
1 |
| Opticians and watchmakers |
1500 |
ww / nw / tw |
2A |
1 |
Einzelplatzbeleuchtung zweckm��ig |
| Jewellery workshops |
1000 |
ww / nw / tw |
2A |
1 |
|
| Working with precious stones |
1500 |
ww / nw / tw |
1B |
1 |
| Radio and television workshops |
500 |
ww / nw |
2A |
1 |
|
Service centers
|
| Reception halls |
200 |
ww / nw |
2A |
1 |
| Kitchen |
500 |
ww / nw |
2A |
2 |
| Dining rooms |
200 |
ww / nw |
1B |
- |
| Living rooms |
300 |
ww / nw |
2A |
1 |
| Self-service restaurants |
300 |
ww / nw |
2B |
1 |
| Hairdressers |
500 |
ww / nw |
1A |
1 |
| Beauticiansk |
750 |
ww / nw / tw |
1A |
1 |
| Laundries and dry cleaners |
| Washing |
300 |
ww / nw |
2A |
2 |
|
| Ironing by machinen |
300 |
ww / nw |
2A |
1 |
| Ironing by hand |
300 |
ww / nw |
2A |
1 |
| Sorting |
300 |
ww / nw |
2A |
1 |
| Spot removal, inspectione |
1000 |
ww / nw |
2A |
1 |
Individual workplace lighting permitted |
|
Au�enanlagen in Lehranstalten
|
| canopied yard |
50 |
ww / nw |
3 |
- |
|
| canopied bicycle stand |
20 |
ww / nw |
3 |
- |
| Treppen, Fahrtreppen und geneigte Verkehrswege |
100 |
ww / nw |
3 |
- |
|
Allgemeine Unterrichtsr�umen
|
| Vorschulr�ume |
300 |
ww / nw |
2 |
1 |
F�r Hauptwandtafel und/oder
Demonstrationstisch
Zusatzbeleuchtung nach DIN 5035 Teil 4, Abschnitt 3.2
1) An den Pl�tzen mindestens 0,8 � En
2) Die f�r andere Nutzung erforderliche Beleuchtungsst�rke kann auch durch Schalten von Teilen der Beleuchtungs-
anlage erreicht werden.
3) Hohe Reflexionsgrade: Decke mind. 0,7, W�nde mind. 0,5 |
| Unterrichtsr�ume, sofern nicht Ziff.4.3 |
3001) |
ww / nw |
2 |
1 |
| Unterrichtsr�ume mit einem Tageslichtquotient D <1% (siehe DIN 5034 Teil 1) am ung�nstigsten Arbeitsplatz sowie f�r vorwiegende Abendnutzung oder speziell f�r Erwachsenenbildung |
5002) |
ww / nw |
2 |
1 |
| Unterrichtsr�ume hohe Reflexion |
750 |
ww / nw |
2 |
1 |
| Unterrichtsr�ume mittlere Reflexion |
1000 |
ww / nw |
2 |
1 |
|
Spezielle Unterrichtsr�ume
|
| Lehrk�chen |
500 |
ww / nw |
2 |
2 |
gegebenenfalls Zusatzbeleuchtung nach DIN 5035 Teil 4, Abschnitt 3.2 |
| Werken |
500 |
ww / nw |
2 |
2 |
| Bastel-, N�h- und Schreibmaschinenr�ume |
500 |
ww / nw |
2 |
1 |
|
| Zeichnen, Malen |
500 |
ww / nw |
1 |
1 |
| Physik, Chemie, Biologie |
500 |
ww / nw |
2 |
1 |
| Laboratorien, experimentelle Praktikumr�ume |
500 |
ww / nww |
2 |
1 |
| Technisches Zeichen 4) |
500 |
ww / nw |
2A |
1 |
| Lehrmittelr�ume |
200 |
ww / nw |
2 |
2 |
| Versammlungsr�ume |
200 |
ww / nw |
2 |
- |
| Bildwerferr�ume |
200 |
ww / nw |
2 |
2 |
| Flure |
100 |
ww / nw |
2 |
3 |
| Treppen |
200 |
ww / nw |
2 |
2 |
| Eingangshallen |
200 |
ww / nw |
2 |
3 |
| Mensen |
200 |
ww / nw |
2 |
1 |
| Ausstellungsr�ume |
200 |
ww / nw |
2 |
2 |
| Mehrzweckr�ume |
200 |
ww / nw |
2 |
1 |
| Aulen, Festr�ume |
200 |
ww / nw |
2 |
1 |
| Bibliotheken, Mediotheken |
200 |
ww / nw |
2 |
1 |
| Leser�ume |
200 |
ww / nw |
2 |
1 |
| Buchmagazine |
200 |
ww / nw |
2 |
2 |
|
H�rs�le
|
| H�rs�le mit Fenster |
500 |
ww / nw |
2 |
1 |
Zusatzbeleuchtung nach DIN 5035 Teil 4, Abschnitt 3.2 |
| H�rs�le ohne Fenster |
750 |
ww / nw |
2 |
1 |